How to deal with the high-voltage vacuum circuit breaker's refusal to close, refusal to open or malfunction stability. At the same time, it is also necessary to check the sealing measures inside the operating mechanism box, and carry out external treatment for the parts that leak due to sealing when it rains, and carry out sealing treatment on the output link arm.

Get A Quote

Equipment professional

Our company took the lead and passed the ISO9001 quality system certification. The company specializes in cooperating with State Grid, South Grid, high and low voltage electrical equipment, and supporting services

Business philosophy

The company has always adhered to the "quality" for survival, reputation, as the leading business philosophy, has an excellent team of engineers, perfect production equipment and after-sales service.

After sales service and technical assistance

With perfect after-sales service and technical assistance services, the company can provide after-sales service and technical support according to customer requirements and needs, and respond in the shortest time.

Efficient production efficiency

The machine ensures the maximum utilization of raw materials, improves the efficiency of the production line, and improves the stability of the customer's products.

about us

We Have The Best Solutions for Your Business

Chongqing Xinsheng Technology Electric Co., Ltd. was founded in 2002 and is located in Chongqing, China, one of the four major municipalities in China.

It is a high-tech company engaged in the research, development, production and sales of pneumatic, air cylinder, high and low voltage electrical, outdoor vacuum circuit breakers, indoor high voltage vacuum circuit breakers, indoor high voltage isolation switches, stainless steel photovoltaic distribution boxes, furniture and household appliances and other products. Technology industry company, its products are widely used in power transmission and distribution, machinery, metallurgy, hydropower, petrochemical, mining, transportation, construction, urban and rural power grid transformation and other power grid home appliance construction projects.

Learn More

Low Pressure Component Maintenance:

The regular cleaning and maintenance of low pressure components such as vacuum pumps and fans is essential for efficient operation, as contaminated filters can obstruct airflow or damage the device.

Low Pressure Component Maintenance:

Features of high voltage vacuum circuit breakers

1. Special anti-condensation measures are adopted inside to ensure the insulation inside the box;

2. The rotation method adopts patented technology, which is easy to install and reliable to operate, and avoids the performance of the circuit breaker due to mechanical failure;

3. No oil, no gas, small size, light weight, no need for maintenance.

4. Large breaking current, no pollution, no need for maintenance.

5. The operation can be electric or manual.

Features of high voltage vacuum circuit breakers

The difference between indoor and outdoor high-voltage isolation switch installation

Outdoor type isolating switch should be installed horizontally when installed in the open air, so that the supporting porcelain bottle with porcelain skirt can indeed play a rainproof role。

Indoor type isolating switch, when installed vertically, the static contact is above, and the ground with sleeve can be installed at a certain angle.

The difference between indoor and outdoor high-voltage isolation switch installation

Applications of High Pressure Components

High pressure components find applications in air compression systems, refrigeration systems, and hydraulic systems. They are commonly used in industries such as oil and gas exploration and drilling, chemical manufacturing, and food and beverage processing.

Applications of High Pressure Components
User Reviews

What users say about Us

The quality is very reliable, looking forward to the next purchase.

Tony

Very impressed with the quality of the sample, and the communication. We have placed a production order as a result.

Eli

I was shocked when I received the product, the quality is very good, very practical and meets my requirements.

Henry

The communication with the supplier was very pleasant and the product provided was very good as I asked, so I placed the order

Vito
Frequently Asked Question

Do you have any question?

1. Control functions: such as the up and down movement of the elevator, automatic switching between fast and slow speeds, and automatic floor stop. 2. Adjustment function: Low-voltage electrical appliances can adjust some electricity and non-electricity to meet the requirements of users.

High-voltage isolation components ensure the safety of high-voltage electrical appliances and devices during maintenance work, and play the role of isolating voltage.

1. Isolation voltage. Ensure that the electrical equipment to be repaired is isolated from the live power grid to ensure that the isolated electrical equipment can be repaired safely. 2. Switching circuit (flip switch operation). In a double busbar wiring circuit, an isolating switch is used to switch electrical equipment or circuits from one set of busbars to another. 3. suitable for small current. Make or break small current circuits